{"id":1581,"date":"2025-10-19T13:10:55","date_gmt":"2025-10-19T09:40:55","guid":{"rendered":"https:\/\/novanirco.com\/?post_type=product&#038;p=1581"},"modified":"2025-12-10T17:03:11","modified_gmt":"2025-12-10T13:33:11","slug":"ten-pair-shielded-underground-60-0-ccam","status":"publish","type":"product","link":"https:\/\/novanirco.com\/en\/product\/ten-pair-shielded-underground-60-0-ccam\/","title":{"rendered":"Ten-pair shielded underground (60\/0 CCAM)"},"content":{"rendered":"<ol data-start=\"0\" data-end=\"20\">\n<li data-start=\"0\" data-end=\"20\">\n<p data-start=\"3\" data-end=\"20\">Technical Section<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"22\" data-end=\"285\"><strong data-start=\"22\" data-end=\"39\">Product Name:<\/strong> \u201cNoan\u2011G10F\u201d Underground Telephone Cable<br data-start=\"79\" data-end=\"82\" \/><strong data-start=\"82\" data-end=\"98\">Application:<\/strong> Underground telephone lines with ten simultaneous pairs, suitable for underground paths, ducts, and indoor environments requiring protection against noise and environmental conditions.<\/p>\n<p data-start=\"287\" data-end=\"311\"><strong data-start=\"287\" data-end=\"309\">Internal Structure<\/strong><\/p>\n<ul data-start=\"312\" data-end=\"921\">\n<li data-start=\"312\" data-end=\"401\">\n<p data-start=\"314\" data-end=\"401\"><strong data-start=\"314\" data-end=\"328\">Conductor:<\/strong> CCAM (Copper\u2011Clad Aluminum) with 60\/0 structure (60 very fine strands)<\/p>\n<\/li>\n<li data-start=\"402\" data-end=\"523\">\n<p data-start=\"404\" data-end=\"523\"><strong data-start=\"404\" data-end=\"433\">Effective Conductor Area:<\/strong> Designed according to project requirements (e.g., approximately ~0.13 mm\u00b2 or ~0.17 mm\u00b2)<\/p>\n<\/li>\n<li data-start=\"524\" data-end=\"565\">\n<p data-start=\"526\" data-end=\"565\"><strong data-start=\"526\" data-end=\"545\">Pair Structure:<\/strong> Ten twisted pairs<\/p>\n<\/li>\n<li data-start=\"566\" data-end=\"669\">\n<p data-start=\"568\" data-end=\"669\"><strong data-start=\"568\" data-end=\"579\">Shield:<\/strong> Laminated aluminum foil longitudinally wrapped around the core assembly (100% coverage)<\/p>\n<\/li>\n<li data-start=\"670\" data-end=\"771\">\n<p data-start=\"672\" data-end=\"771\"><strong data-start=\"672\" data-end=\"687\">Drain Wire:<\/strong> Auxiliary conductor (copper or tinned copper) for connecting the shield to ground<\/p>\n<\/li>\n<li data-start=\"772\" data-end=\"844\">\n<p data-start=\"774\" data-end=\"844\"><strong data-start=\"774\" data-end=\"803\">Insulation per Conductor:<\/strong> PVC or PE suitable for underground use<\/p>\n<\/li>\n<li data-start=\"845\" data-end=\"921\">\n<p data-start=\"847\" data-end=\"921\"><strong data-start=\"847\" data-end=\"864\">Outer Jacket:<\/strong> UV-resistant PVC or composite for outdoor installation<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"923\" data-end=\"970\"><strong data-start=\"923\" data-end=\"968\">Electrical and Performance Specifications<\/strong><\/p>\n<ul data-start=\"971\" data-end=\"1535\">\n<li data-start=\"971\" data-end=\"1070\">\n<p data-start=\"973\" data-end=\"1070\"><strong data-start=\"973\" data-end=\"996\">Conductor Diameter:<\/strong> According to a similar 10-pair reference cable with ~0.60 mm conductors<\/p>\n<\/li>\n<li data-start=\"1071\" data-end=\"1149\">\n<p data-start=\"1073\" data-end=\"1149\"><strong data-start=\"1073\" data-end=\"1113\">Conductor Resistance at 20\u202f\u00b0C (Max):<\/strong> \u2264 186 \u03a9\/km for ~0.60 mm conductor<\/p>\n<\/li>\n<li data-start=\"1150\" data-end=\"1199\">\n<p data-start=\"1152\" data-end=\"1199\"><strong data-start=\"1152\" data-end=\"1184\">Insulation Resistance (Min):<\/strong> \u2265 5000 M\u03a9\u00b7km<\/p>\n<\/li>\n<li data-start=\"1200\" data-end=\"1277\">\n<p data-start=\"1202\" data-end=\"1277\"><strong data-start=\"1202\" data-end=\"1219\">Test Voltage:<\/strong> AC 1500 V (1 min) \/ DC 2250 V (1 min) without breakdown<\/p>\n<\/li>\n<li data-start=\"1278\" data-end=\"1325\">\n<p data-start=\"1280\" data-end=\"1325\"><strong data-start=\"1280\" data-end=\"1306\">Operating Temperature:<\/strong> \u201120 \u00b0C to +60 \u00b0C<\/p>\n<\/li>\n<li data-start=\"1326\" data-end=\"1430\">\n<p data-start=\"1328\" data-end=\"1430\"><strong data-start=\"1328\" data-end=\"1358\">Capacitance and Impedance:<\/strong> Twisted pair design minimizes crosstalk and pair-to-pair interference<\/p>\n<\/li>\n<li data-start=\"1431\" data-end=\"1535\">\n<p data-start=\"1433\" data-end=\"1535\"><strong data-start=\"1433\" data-end=\"1460\">Minimum Bending Radius:<\/strong> 10\u00d7 the overall cable diameter (or according to manufacturer guidelines)<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1537\" data-end=\"1577\"><strong data-start=\"1537\" data-end=\"1575\">Installation and Maintenance Notes<\/strong><\/p>\n<ul data-start=\"1578\" data-end=\"1897\">\n<li data-start=\"1578\" data-end=\"1634\">\n<p data-start=\"1580\" data-end=\"1634\">Install in ducts, underground, or protected pathways<\/p>\n<\/li>\n<li data-start=\"1635\" data-end=\"1695\">\n<p data-start=\"1637\" data-end=\"1695\">Protect passage points with clamps or protective sleeves<\/p>\n<\/li>\n<li data-start=\"1696\" data-end=\"1766\">\n<p data-start=\"1698\" data-end=\"1766\">Connect shield to ground at a single point for optimal performance<\/p>\n<\/li>\n<li data-start=\"1767\" data-end=\"1816\">\n<p data-start=\"1769\" data-end=\"1816\">Maintain bending radius and avoid sharp bends<\/p>\n<\/li>\n<li data-start=\"1817\" data-end=\"1897\">\n<p data-start=\"1819\" data-end=\"1897\">After installation, perform insulation resistance and line performance tests<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"1899\" data-end=\"1902\" \/>\n<ol start=\"2\" data-start=\"1904\" data-end=\"1922\">\n<li data-start=\"1904\" data-end=\"1922\">\n<p data-start=\"1907\" data-end=\"1922\">Content Section<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"1924\" data-end=\"1987\"><strong data-start=\"1924\" data-end=\"1985\">Ten-Pair Shielded Underground Telephone Cable \u201cNoan\u2011G10F\u201d<\/strong><\/p>\n<p data-start=\"1989\" data-end=\"2627\">Noavar Niroo Paytakht Company is proud to introduce the \u201cNoan\u2011G10F\u201d cable; this \u201cten-pair underground telephone cable with full foil shielding\u201d is designed for indoor and underground environments requiring simultaneous transmission of multiple telephone lines. Lightweight CCAM conductors with 60\/0 strand structure, combined with proper insulation and aluminum shielding, ensure high performance against environmental interference. The \u201cNoan\u2011G10F\u201d cable is suitable for urban or intercity projects needing multiple telephone lines along an underground path, providing environmental durability, stable signals, and reliable performance.<\/p>\n<p data-start=\"2629\" data-end=\"2648\"><strong data-start=\"2629\" data-end=\"2646\">Key Features:<\/strong><\/p>\n<ul data-start=\"2649\" data-end=\"2918\">\n<li data-start=\"2649\" data-end=\"2670\">\n<p data-start=\"2651\" data-end=\"2670\">Ten twisted pairs<\/p>\n<\/li>\n<li data-start=\"2671\" data-end=\"2716\">\n<p data-start=\"2673\" data-end=\"2716\">Full foil shield around the core assembly<\/p>\n<\/li>\n<li data-start=\"2717\" data-end=\"2768\">\n<p data-start=\"2719\" data-end=\"2768\">Lightweight CCAM conductors with 60\/0 structure<\/p>\n<\/li>\n<li data-start=\"2769\" data-end=\"2826\">\n<p data-start=\"2771\" data-end=\"2826\">Robust design for indoor and underground installation<\/p>\n<\/li>\n<li data-start=\"2827\" data-end=\"2857\">\n<p data-start=\"2829\" data-end=\"2857\">High insulation resistance<\/p>\n<\/li>\n<li data-start=\"2858\" data-end=\"2918\">\n<p data-start=\"2860\" data-end=\"2918\">Reliable performance in various environmental conditions<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"2920\" data-end=\"2923\" \/>\n<ol start=\"3\" data-start=\"2925\" data-end=\"2981\">\n<li data-start=\"2925\" data-end=\"2981\">\n<p data-start=\"2928\" data-end=\"2981\">Description, Applications, and Comparative Analysis<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"2983\" data-end=\"3011\"><strong data-start=\"2983\" data-end=\"3009\">Suitable Applications:<\/strong><\/p>\n<ul data-start=\"3012\" data-end=\"3256\">\n<li data-start=\"3012\" data-end=\"3071\">\n<p data-start=\"3014\" data-end=\"3071\">Underground telephone lines with a high number of pairs<\/p>\n<\/li>\n<li data-start=\"3072\" data-end=\"3130\">\n<p data-start=\"3074\" data-end=\"3130\">Underground or in-structure routes in telecom projects<\/p>\n<\/li>\n<li data-start=\"3131\" data-end=\"3189\">\n<p data-start=\"3133\" data-end=\"3189\">Areas with high electromagnetic interference potential<\/p>\n<\/li>\n<li data-start=\"3190\" data-end=\"3256\">\n<p data-start=\"3192\" data-end=\"3256\">Urban or rural areas requiring multiple lines in a single path<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3258\" data-end=\"3275\"><strong data-start=\"3258\" data-end=\"3273\">Advantages:<\/strong><\/p>\n<ul data-start=\"3276\" data-end=\"3569\">\n<li data-start=\"3276\" data-end=\"3352\">\n<p data-start=\"3278\" data-end=\"3352\">Supports multiple telephone lines simultaneously without separate cables<\/p>\n<\/li>\n<li data-start=\"3353\" data-end=\"3430\">\n<p data-start=\"3355\" data-end=\"3430\">Effective protection against environmental noise thanks to foil shielding<\/p>\n<\/li>\n<li data-start=\"3431\" data-end=\"3503\">\n<p data-start=\"3433\" data-end=\"3503\">Reduces installation cost by using a single cable for multiple pairs<\/p>\n<\/li>\n<li data-start=\"3504\" data-end=\"3569\">\n<p data-start=\"3506\" data-end=\"3569\">Lighter weight and lower cost compared to fully copper cables<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3571\" data-end=\"3591\"><strong data-start=\"3571\" data-end=\"3589\">Disadvantages:<\/strong><\/p>\n<ul data-start=\"3592\" data-end=\"3842\">\n<li data-start=\"3592\" data-end=\"3648\">\n<p data-start=\"3594\" data-end=\"3648\">Higher conductor resistance than fully copper cables<\/p>\n<\/li>\n<li data-start=\"3649\" data-end=\"3721\">\n<p data-start=\"3651\" data-end=\"3721\">Shield performance reduces if grounding is not correctly implemented<\/p>\n<\/li>\n<li data-start=\"3722\" data-end=\"3786\">\n<p data-start=\"3724\" data-end=\"3786\">Precise installation and adherence to standards are critical<\/p>\n<\/li>\n<li data-start=\"3787\" data-end=\"3842\">\n<p data-start=\"3789\" data-end=\"3842\">Signal loss may be noticeable over longer distances<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3844\" data-end=\"3884\"><strong data-start=\"3844\" data-end=\"3882\">Comparison with Lower-Pair Models:<\/strong><\/p>\n<ul data-start=\"3885\" data-end=\"4183\">\n<li data-start=\"3885\" data-end=\"4061\">\n<p data-start=\"3887\" data-end=\"4061\">Compared to one- or two-pair cables, the ten-pair cable has higher core density, which may increase crosstalk; precise twisted pair length and continuous foil are essential<\/p>\n<\/li>\n<li data-start=\"4062\" data-end=\"4183\">\n<p data-start=\"4064\" data-end=\"4183\">Production cost is relatively higher, but the benefit of transmitting multiple lines in a single cable is significant<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4185\" data-end=\"4232\"><strong data-start=\"4185\" data-end=\"4230\">Quality Assurance and Production Control:<\/strong><\/p>\n<ul data-start=\"4233\" data-end=\"4614\" data-is-last-node=\"\" data-is-only-node=\"\">\n<li data-start=\"4233\" data-end=\"4300\">\n<p data-start=\"4235\" data-end=\"4300\">Accurate strand count (60 strands) and uniformity of conductors<\/p>\n<\/li>\n<li data-start=\"4301\" data-end=\"4350\">\n<p data-start=\"4303\" data-end=\"4350\">Ensured foil thickness, adhesion, and quality<\/p>\n<\/li>\n<li data-start=\"4351\" data-end=\"4434\">\n<p data-start=\"4353\" data-end=\"4434\">Insulation testing, thermal aging, mechanical and vibration testing for samples<\/p>\n<\/li>\n<li data-start=\"4435\" data-end=\"4533\">\n<p data-start=\"4437\" data-end=\"4533\">Product name, company name, technical specifications, and production date printed on the cable<\/p>\n<\/li>\n<li data-start=\"4534\" data-end=\"4614\" data-is-last-node=\"\">\n<p data-start=\"4536\" data-end=\"4614\" data-is-last-node=\"\">Delivery of insulation resistance and performance test reports to the customer<\/p>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Technical Section Product Name: \u201cNoan\u2011G10F\u201d Underground Telephone CableApplication: Underground telephone lines with ten simultaneous pairs, suitable for underground paths, ducts,<\/p>\n","protected":false},"featured_media":1582,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[154,153,150],"product_tag":[],"class_list":{"0":"post-1581","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ccam-terrestrial-twisted-pair-cable","7":"product_cat-paired-cable","8":"product_cat-wire-and-cable","10":"first","11":"instock","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product\/1581","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/comments?post=1581"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/media\/1582"}],"wp:attachment":[{"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/media?parent=1581"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product_brand?post=1581"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product_cat?post=1581"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product_tag?post=1581"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}