{"id":1602,"date":"2025-10-19T13:39:01","date_gmt":"2025-10-19T10:09:01","guid":{"rendered":"https:\/\/novanirco.com\/?post_type=product&#038;p=1602"},"modified":"2025-12-10T15:43:17","modified_gmt":"2025-12-10T12:13:17","slug":"twenty-pair-aerial-foil-shielded-cable-60-0-ccam","status":"publish","type":"product","link":"https:\/\/novanirco.com\/en\/product\/twenty-pair-aerial-foil-shielded-cable-60-0-ccam\/","title":{"rendered":"Twenty-pair aerial foil-shielded cable (60\/0 CCAM)"},"content":{"rendered":"<h3 data-start=\"0\" data-end=\"24\">1. Technical Section<\/h3>\n<p data-start=\"26\" data-end=\"78\"><strong data-start=\"26\" data-end=\"43\">Product Name:<\/strong> Noan\u2011A20F Aerial Telephone Cable<\/p>\n<p data-start=\"80\" data-end=\"239\"><strong data-start=\"80\" data-end=\"96\">Application:<\/strong> Aerial telephone lines with twenty pairs, suitable for spans between poles where noise protection and environmental resistance are required.<\/p>\n<p data-start=\"241\" data-end=\"266\"><strong data-start=\"241\" data-end=\"264\">Internal Structure:<\/strong><\/p>\n<ul data-start=\"267\" data-end=\"871\">\n<li data-start=\"267\" data-end=\"364\">\n<p data-start=\"269\" data-end=\"364\"><strong data-start=\"269\" data-end=\"283\">Conductor:<\/strong> CCAM (Copper-Clad Aluminum) with 60\/0 stranded configuration (60 fine strands)<\/p>\n<\/li>\n<li data-start=\"365\" data-end=\"483\">\n<p data-start=\"367\" data-end=\"483\"><strong data-start=\"367\" data-end=\"396\">Effective Conductor Area:<\/strong> Designed according to project requirements (e.g., ~0.13\u202fmm\u00b2 or ~0.17\u202fmm\u00b2 equivalent)<\/p>\n<\/li>\n<li data-start=\"484\" data-end=\"524\">\n<p data-start=\"486\" data-end=\"524\"><strong data-start=\"486\" data-end=\"505\">Pair Structure:<\/strong> 20 twisted pairs<\/p>\n<\/li>\n<li data-start=\"525\" data-end=\"626\">\n<p data-start=\"527\" data-end=\"626\"><strong data-start=\"527\" data-end=\"538\">Shield:<\/strong> Laminated aluminum foil longitudinally wrapped around the entire core (100% coverage)<\/p>\n<\/li>\n<li data-start=\"627\" data-end=\"715\">\n<p data-start=\"629\" data-end=\"715\"><strong data-start=\"629\" data-end=\"644\">Drain Wire:<\/strong> Auxiliary copper or tinned copper conductor for grounding the shield<\/p>\n<\/li>\n<li data-start=\"716\" data-end=\"776\">\n<p data-start=\"718\" data-end=\"776\"><strong data-start=\"718\" data-end=\"733\">Insulation:<\/strong> PVC or PE for aerial\/ground applications<\/p>\n<\/li>\n<li data-start=\"777\" data-end=\"871\">\n<p data-start=\"779\" data-end=\"871\"><strong data-start=\"779\" data-end=\"796\">Outer Jacket:<\/strong> UV-resistant PVC or a composite jacket suitable for outdoor installation<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"873\" data-end=\"919\"><strong data-start=\"873\" data-end=\"917\">Electrical &amp; Performance Specifications:<\/strong><\/p>\n<ul data-start=\"920\" data-end=\"1423\">\n<li data-start=\"920\" data-end=\"985\">\n<p data-start=\"922\" data-end=\"985\"><strong data-start=\"922\" data-end=\"945\">Conductor Diameter:<\/strong> Reference ~0.60\u202fmm for 20-pair cables<\/p>\n<\/li>\n<li data-start=\"986\" data-end=\"1061\">\n<p data-start=\"988\" data-end=\"1061\"><strong data-start=\"988\" data-end=\"1026\">Conductor Resistance @20\u202f\u00b0C (max):<\/strong> \u2264186\u202f\u03a9\/km for ~0.60\u202fmm conductor<\/p>\n<\/li>\n<li data-start=\"1062\" data-end=\"1110\">\n<p data-start=\"1064\" data-end=\"1110\"><strong data-start=\"1064\" data-end=\"1096\">Insulation Resistance (min):<\/strong> \u22655000\u202fM\u03a9\u00b7km<\/p>\n<\/li>\n<li data-start=\"1111\" data-end=\"1180\">\n<p data-start=\"1113\" data-end=\"1180\"><strong data-start=\"1113\" data-end=\"1130\">Test Voltage:<\/strong> AC 1500\u202fV \/ DC 2250\u202fV (1\u202fmin) without breakdown<\/p>\n<\/li>\n<li data-start=\"1181\" data-end=\"1228\">\n<p data-start=\"1183\" data-end=\"1228\"><strong data-start=\"1183\" data-end=\"1209\">Operating Temperature:<\/strong> \u221220\u202f\u00b0C to +60\u202f\u00b0C<\/p>\n<\/li>\n<li data-start=\"1229\" data-end=\"1329\">\n<p data-start=\"1231\" data-end=\"1329\"><strong data-start=\"1231\" data-end=\"1259\">Capacitance &amp; Impedance:<\/strong> Pair twist designed to reduce crosstalk and inter-pair interference<\/p>\n<\/li>\n<li data-start=\"1330\" data-end=\"1423\">\n<p data-start=\"1332\" data-end=\"1423\"><strong data-start=\"1332\" data-end=\"1359\">Minimum Bending Radius:<\/strong> 10\u00d7 overall cable diameter (or per manufacturer instructions)<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1425\" data-end=\"1458\"><strong data-start=\"1425\" data-end=\"1456\">Installation &amp; Maintenance:<\/strong><\/p>\n<ul data-start=\"1459\" data-end=\"1750\">\n<li data-start=\"1459\" data-end=\"1512\">\n<p data-start=\"1461\" data-end=\"1512\">Install in ducts, underground, or protected paths<\/p>\n<\/li>\n<li data-start=\"1513\" data-end=\"1583\">\n<p data-start=\"1515\" data-end=\"1583\">Protect cable at crossing points with clamps or protective sleeves<\/p>\n<\/li>\n<li data-start=\"1584\" data-end=\"1630\">\n<p data-start=\"1586\" data-end=\"1630\">Connect shield to ground at a single point<\/p>\n<\/li>\n<li data-start=\"1631\" data-end=\"1679\">\n<p data-start=\"1633\" data-end=\"1679\">Avoid sharp bends and respect bending radius<\/p>\n<\/li>\n<li data-start=\"1680\" data-end=\"1750\">\n<p data-start=\"1682\" data-end=\"1750\">Post-installation, test insulation resistance and line performance<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"1752\" data-end=\"1755\" \/>\n<h3 data-start=\"1757\" data-end=\"1791\">2. Marketing \/ Content Section<\/h3>\n<p data-start=\"1793\" data-end=\"1910\"><strong data-start=\"1793\" data-end=\"1820\">Official Product Title:<\/strong><br data-start=\"1820\" data-end=\"1823\" \/>Noan\u2011A20F \u2014 20-Pair Aerial Telephone Cable with Full Foil Shield, 60\/0 CCAM Conductor<\/p>\n<p data-start=\"1912\" data-end=\"2507\"><strong data-start=\"1912\" data-end=\"1936\">Product Description:<\/strong><br data-start=\"1936\" data-end=\"1939\" \/>Noanir proudly introduces the <strong data-start=\"1969\" data-end=\"1982\">Noan\u2011A20F<\/strong> cable, a <strong data-start=\"1992\" data-end=\"2051\">20-pair aerial telephone cable with full foil shielding<\/strong>, designed for outdoor environments requiring simultaneous transmission of multiple telephone lines. The lightweight CCAM conductor with 60\/0 strand construction, combined with proper insulation and aluminum foil shielding, ensures high performance against environmental interference. The Noan\u2011A20F is ideal for urban or intercity projects requiring multiple lines on aerial spans, offering durability, stable signal transmission, and reliable operation.<\/p>\n<p data-start=\"2509\" data-end=\"2528\"><strong data-start=\"2509\" data-end=\"2526\">Key Features:<\/strong><\/p>\n<ul data-start=\"2529\" data-end=\"2773\">\n<li data-start=\"2529\" data-end=\"2549\">\n<p data-start=\"2531\" data-end=\"2549\">20 twisted pairs<\/p>\n<\/li>\n<li data-start=\"2550\" data-end=\"2586\">\n<p data-start=\"2552\" data-end=\"2586\">Full foil shield around the core<\/p>\n<\/li>\n<li data-start=\"2587\" data-end=\"2631\">\n<p data-start=\"2589\" data-end=\"2631\">Lightweight CCAM conductor, 60\/0 strands<\/p>\n<\/li>\n<li data-start=\"2632\" data-end=\"2690\">\n<p data-start=\"2634\" data-end=\"2690\">Durable design for aerial and underground installation<\/p>\n<\/li>\n<li data-start=\"2691\" data-end=\"2721\">\n<p data-start=\"2693\" data-end=\"2721\">High insulation resistance<\/p>\n<\/li>\n<li data-start=\"2722\" data-end=\"2773\">\n<p data-start=\"2724\" data-end=\"2773\">Reliable performance under environmental stress<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"2775\" data-end=\"2778\" \/>\n<h3 data-start=\"2780\" data-end=\"2837\">3. Applications, Advantages, and Comparative Analysis<\/h3>\n<p data-start=\"2839\" data-end=\"2867\"><strong data-start=\"2839\" data-end=\"2865\">Suitable Applications:<\/strong><\/p>\n<ul data-start=\"2868\" data-end=\"3095\">\n<li data-start=\"2868\" data-end=\"2922\">\n<p data-start=\"2870\" data-end=\"2922\">Ground telephone lines with a high number of pairs<\/p>\n<\/li>\n<li data-start=\"2923\" data-end=\"2979\">\n<p data-start=\"2925\" data-end=\"2979\">Underground or in-building telecommunications routes<\/p>\n<\/li>\n<li data-start=\"2980\" data-end=\"3028\">\n<p data-start=\"2982\" data-end=\"3028\">Areas with high electromagnetic interference<\/p>\n<\/li>\n<li data-start=\"3029\" data-end=\"3095\">\n<p data-start=\"3031\" data-end=\"3095\">Urban or rural regions needing multiple lines on a single path<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3097\" data-end=\"3114\"><strong data-start=\"3097\" data-end=\"3112\">Advantages:<\/strong><\/p>\n<ul data-start=\"3115\" data-end=\"3349\">\n<li data-start=\"3115\" data-end=\"3160\">\n<p data-start=\"3117\" data-end=\"3160\">Multiple lines provided in a single cable<\/p>\n<\/li>\n<li data-start=\"3161\" data-end=\"3210\">\n<p data-start=\"3163\" data-end=\"3210\">Effective noise protection via foil shielding<\/p>\n<\/li>\n<li data-start=\"3211\" data-end=\"3283\">\n<p data-start=\"3213\" data-end=\"3283\">Reduced installation cost by using a single cable for multiple pairs<\/p>\n<\/li>\n<li data-start=\"3284\" data-end=\"3349\">\n<p data-start=\"3286\" data-end=\"3349\">Lighter and more cost-effective than full-copper alternatives<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3351\" data-end=\"3369\"><strong data-start=\"3351\" data-end=\"3367\">Limitations:<\/strong><\/p>\n<ul data-start=\"3370\" data-end=\"3609\">\n<li data-start=\"3370\" data-end=\"3432\">\n<p data-start=\"3372\" data-end=\"3432\">Higher conductor resistance compared to pure copper cables<\/p>\n<\/li>\n<li data-start=\"3433\" data-end=\"3489\">\n<p data-start=\"3435\" data-end=\"3489\">Shield efficiency decreases if grounding is improper<\/p>\n<\/li>\n<li data-start=\"3490\" data-end=\"3550\">\n<p data-start=\"3492\" data-end=\"3550\">Careful installation and adherence to standards required<\/p>\n<\/li>\n<li data-start=\"3551\" data-end=\"3609\">\n<p data-start=\"3553\" data-end=\"3609\">Signal loss may be noticeable over very long distances<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3611\" data-end=\"3651\"><strong data-start=\"3611\" data-end=\"3649\">Comparison with Lower-Pair Models:<\/strong><\/p>\n<ul data-start=\"3652\" data-end=\"3865\">\n<li data-start=\"3652\" data-end=\"3762\">\n<p data-start=\"3654\" data-end=\"3762\">Higher core density may increase inter-pair crosstalk; proper pair twist and continuous foil are essential<\/p>\n<\/li>\n<li data-start=\"3763\" data-end=\"3865\">\n<p data-start=\"3765\" data-end=\"3865\">Production cost is higher, but operational advantage of multiple lines in one cable is significant<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3867\" data-end=\"3912\"><strong data-start=\"3867\" data-end=\"3910\">Quality Assurance &amp; Production Control:<\/strong><\/p>\n<ul data-start=\"3913\" data-end=\"4247\" data-is-last-node=\"\" data-is-only-node=\"\">\n<li data-start=\"3913\" data-end=\"3977\">\n<p data-start=\"3915\" data-end=\"3977\">Strict control of strand count (60) and conductor uniformity<\/p>\n<\/li>\n<li data-start=\"3978\" data-end=\"4028\">\n<p data-start=\"3980\" data-end=\"4028\">Verified foil thickness, adhesion, and quality<\/p>\n<\/li>\n<li data-start=\"4029\" data-end=\"4093\">\n<p data-start=\"4031\" data-end=\"4093\">Insulation, thermal aging, mechanical, and vibration testing<\/p>\n<\/li>\n<li data-start=\"4094\" data-end=\"4169\">\n<p data-start=\"4096\" data-end=\"4169\">Product marking with Noanir brand, technical specs, and production date<\/p>\n<\/li>\n<li data-start=\"4170\" data-end=\"4247\" data-is-last-node=\"\">\n<p data-start=\"4172\" data-end=\"4247\" data-is-last-node=\"\">Delivery of insulation resistance and performance test reports to customers<\/p>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>\u0628\u0633\u062a\u0647 \u0628\u0646\u062f\u06cc \u06a9\u0627\u0631\u062a\u0646<\/p>\n","protected":false},"featured_media":1575,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[153,150,156],"product_tag":[],"class_list":{"0":"post-1602","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-paired-cable","7":"product_cat-wire-and-cable","8":"product_cat----ccam","10":"first","11":"instock","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product\/1602","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/comments?post=1602"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/media\/1575"}],"wp:attachment":[{"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/media?parent=1602"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product_brand?post=1602"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product_cat?post=1602"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product_tag?post=1602"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}