{"id":1603,"date":"2025-10-19T13:56:00","date_gmt":"2025-10-19T10:26:00","guid":{"rendered":"https:\/\/novanirco.com\/?post_type=product&#038;p=1603"},"modified":"2025-12-10T15:41:29","modified_gmt":"2025-12-10T12:11:29","slug":"six-pair-foil-shielded-aerial-cable-60-0-cu","status":"publish","type":"product","link":"https:\/\/novanirco.com\/en\/product\/six-pair-foil-shielded-aerial-cable-60-0-cu\/","title":{"rendered":"Six-pair, foil-shielded aerial cable (60\/0 CU)"},"content":{"rendered":"<h3 data-start=\"63\" data-end=\"87\">1. Technical Section<\/h3>\n<p data-start=\"89\" data-end=\"168\"><strong data-start=\"89\" data-end=\"106\">Product Name:<\/strong> Aerial Six-Pair Foil-Shielded Telephone Cable \u00abNoan-A6CCAM\u00bb<\/p>\n<p data-start=\"170\" data-end=\"392\"><strong data-start=\"170\" data-end=\"194\">General Application:<\/strong><br data-start=\"194\" data-end=\"197\" \/>Aerial cable for subscriber drop lines and short-distance outdoor telephone lines (installation on poles or aerial paths) requiring shield protection against electromagnetic interference (EMI).<\/p>\n<p data-start=\"394\" data-end=\"463\"><strong data-start=\"394\" data-end=\"461\">Structure and Materials (Manufacturer-Oriented Specifications):<\/strong><\/p>\n<ul data-start=\"464\" data-end=\"1300\">\n<li data-start=\"464\" data-end=\"597\">\n<p data-start=\"466\" data-end=\"597\"><strong data-start=\"466\" data-end=\"480\">Conductor:<\/strong> Aluminum-copper (CCAM) with 60\/0 stranded construction \u2014 chosen for flexibility and reliable terminal connections.<\/p>\n<\/li>\n<li data-start=\"598\" data-end=\"764\">\n<p data-start=\"600\" data-end=\"764\"><strong data-start=\"600\" data-end=\"647\">Reference Conductor Diameter\/Cross-Section:<\/strong> Nominal ~0.50\u20130.60 mm (commercial designation \u201c06\u201d or 0.6 mm). Exact cross-section finalized per production order.<\/p>\n<\/li>\n<li data-start=\"765\" data-end=\"927\">\n<p data-start=\"767\" data-end=\"927\"><strong data-start=\"767\" data-end=\"793\">Individual Insulation:<\/strong> Polyethylene (PE) or telecommunications-grade PVC, depending on fire resistance\/flexibility requirements; each pair is color-coded.<\/p>\n<\/li>\n<li data-start=\"928\" data-end=\"1065\">\n<p data-start=\"930\" data-end=\"1065\"><strong data-start=\"930\" data-end=\"941\">Shield:<\/strong> Aluminum-polyester laminated foil covering 100% of the core, reducing environmental noise and enhancing signal integrity.<\/p>\n<\/li>\n<li data-start=\"1066\" data-end=\"1180\">\n<p data-start=\"1068\" data-end=\"1180\"><strong data-start=\"1068\" data-end=\"1083\">Drain Wire:<\/strong> Small-diameter tinned copper or copper wire to connect the shield to ground at a single point.<\/p>\n<\/li>\n<li data-start=\"1181\" data-end=\"1300\">\n<p data-start=\"1183\" data-end=\"1300\"><strong data-start=\"1183\" data-end=\"1200\">Outer Jacket:<\/strong> UV-resistant PVC or PVC-PE blend suitable for aerial installation; common colors are earth\/black.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1302\" data-end=\"1378\"><strong data-start=\"1302\" data-end=\"1376\">Electrical and Performance Features (Reference from Similar Products):<\/strong><\/p>\n<ul data-start=\"1379\" data-end=\"1932\">\n<li data-start=\"1379\" data-end=\"1497\">\n<p data-start=\"1381\" data-end=\"1497\">Conductor resistance depends on final diameter (~0.6 mm for market references, labeled as \u201c6-pair 0.6 aerial CU\u201d).<\/p>\n<\/li>\n<li data-start=\"1498\" data-end=\"1672\">\n<p data-start=\"1500\" data-end=\"1672\">Capacitance and impedance: Designed for EMI reduction; exact pair impedance is not specified like network cables. Proper lay length is essential for minimizing crosstalk.<\/p>\n<\/li>\n<li data-start=\"1673\" data-end=\"1779\">\n<p data-start=\"1675\" data-end=\"1779\">Operating temperature: -20 \u00b0C to +60 \u00b0C, depending on jacket composition and environmental conditions.<\/p>\n<\/li>\n<li data-start=\"1780\" data-end=\"1932\">\n<p data-start=\"1782\" data-end=\"1932\">Quality tests: insulation resistance, dielectric, thermal aging, UV exposure, and mechanical stress\/shock tests performed on pre-production samples.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1934\" data-end=\"1984\"><strong data-start=\"1934\" data-end=\"1982\">Dimensions, Packaging, and Production Notes:<\/strong><\/p>\n<ul data-start=\"1985\" data-end=\"2385\">\n<li data-start=\"1985\" data-end=\"2063\">\n<p data-start=\"1987\" data-end=\"2063\">Standard coil length: 250 m or 500 m, adjustable per project requirements.<\/p>\n<\/li>\n<li data-start=\"2064\" data-end=\"2223\">\n<p data-start=\"2066\" data-end=\"2223\">Packaging: Coil with proper core, identification card with production date, batch number, conductor specs (60\/0 CCAM), insulation type, and shield details.<\/p>\n<\/li>\n<li data-start=\"2224\" data-end=\"2385\">\n<p data-start=\"2226\" data-end=\"2385\">Production considerations: uniform strand count (60) in each conductor, proper foil-polyester adhesion, jacket UV durability, and electrical tests per batch.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2387\" data-end=\"2434\"><strong data-start=\"2387\" data-end=\"2432\">Field Installation and Maintenance Notes:<\/strong><\/p>\n<ul data-start=\"2435\" data-end=\"2830\">\n<li data-start=\"2435\" data-end=\"2542\">\n<p data-start=\"2437\" data-end=\"2542\">Install aerially using messenger or spacers\/clamps per guidelines; adhere to maximum allowable tension.<\/p>\n<\/li>\n<li data-start=\"2543\" data-end=\"2613\">\n<p data-start=\"2545\" data-end=\"2613\">Connect shield to ground at a single point to prevent earth loops.<\/p>\n<\/li>\n<li data-start=\"2614\" data-end=\"2710\">\n<p data-start=\"2616\" data-end=\"2710\">Post-installation tests: insulation resistance and line performance (call room\/line sensor).<\/p>\n<\/li>\n<li data-start=\"2711\" data-end=\"2830\">\n<p data-start=\"2713\" data-end=\"2830\">Use guards or protective sleeves where cables pass poles or contact mechanical surfaces to prevent jacket abrasion.<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"2837\" data-end=\"2893\">2. Product Description (for Website, Catalog, Label)<\/h3>\n<p data-start=\"2895\" data-end=\"3037\"><strong data-start=\"2895\" data-end=\"2914\">Official Title:<\/strong><br data-start=\"2914\" data-end=\"2917\" \/>Aerial Six-Pair Foil-Shielded Telephone Cable \u00abNoan-A6CCAM\u00bb \u2014 Full Shield, 60\/0 CCAM Conductor, Ideal for Aerial Lines<\/p>\n<p data-start=\"3039\" data-end=\"3603\"><strong data-start=\"3039\" data-end=\"3055\">Description:<\/strong><br data-start=\"3055\" data-end=\"3058\" \/>Noan-A6CCAM is designed for aerial telecommunications applications. This six-pair cable uses CCAM 60\/0 conductors for maximum flexibility and secure terminal connections. The core is fully shielded with aluminum-polyester foil and includes a copper drain wire for single-point grounding, providing strong EMI protection and stable signal transmission. The UV-resistant outer jacket ensures long-term durability in outdoor aerial installations. Ideal for drop lines, subscriber connections, and urban telephone lines requiring noise protection.<\/p>\n<p data-start=\"3605\" data-end=\"3624\"><strong data-start=\"3605\" data-end=\"3622\">Key Features:<\/strong><\/p>\n<ul data-start=\"3625\" data-end=\"4008\">\n<li data-start=\"3625\" data-end=\"3658\">\n<p data-start=\"3627\" data-end=\"3658\">Conductor: CCAM 60\/0 stranded<\/p>\n<\/li>\n<li data-start=\"3659\" data-end=\"3712\">\n<p data-start=\"3661\" data-end=\"3712\">Shield: Aluminum-polyester foil with copper drain<\/p>\n<\/li>\n<li data-start=\"3713\" data-end=\"3757\">\n<p data-start=\"3715\" data-end=\"3757\">Insulation: PE\/PVC, color-coded per pair<\/p>\n<\/li>\n<li data-start=\"3758\" data-end=\"3816\">\n<p data-start=\"3760\" data-end=\"3816\">Outer jacket: UV-resistant PVC for aerial installation<\/p>\n<\/li>\n<li data-start=\"3817\" data-end=\"3897\">\n<p data-start=\"3819\" data-end=\"3897\">Applications: Drop\/air lines, subscriber connections, short-to-medium routes<\/p>\n<\/li>\n<li data-start=\"3898\" data-end=\"3938\">\n<p data-start=\"3900\" data-end=\"3938\">Packaging: 250 m coil (customizable)<\/p>\n<\/li>\n<li data-start=\"3939\" data-end=\"4008\">\n<p data-start=\"3941\" data-end=\"4008\">Tests: Insulation resistance, tensile, thermal aging, UV exposure<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"4015\" data-end=\"4072\">3. Applications, Advantages, and Comparative Analysis<\/h3>\n<p data-start=\"4074\" data-end=\"4093\"><strong data-start=\"4074\" data-end=\"4091\">Applications:<\/strong><\/p>\n<ul data-start=\"4094\" data-end=\"4333\">\n<li data-start=\"4094\" data-end=\"4165\">\n<p data-start=\"4096\" data-end=\"4165\">Aerial subscriber drop from distribution cable to subscriber panel.<\/p>\n<\/li>\n<li data-start=\"4166\" data-end=\"4238\">\n<p data-start=\"4168\" data-end=\"4238\">Telephone lines and low-speed data in urban and rural aerial routes.<\/p>\n<\/li>\n<li data-start=\"4239\" data-end=\"4333\">\n<p data-start=\"4241\" data-end=\"4333\">Situations requiring quick installation and reduced weight compared to full-copper cables.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4335\" data-end=\"4352\"><strong data-start=\"4335\" data-end=\"4350\">Advantages:<\/strong><\/p>\n<ul data-start=\"4353\" data-end=\"4594\">\n<li data-start=\"4353\" data-end=\"4418\">\n<p data-start=\"4355\" data-end=\"4418\">Strong EMI protection with full foil shield and copper drain.<\/p>\n<\/li>\n<li data-start=\"4419\" data-end=\"4496\">\n<p data-start=\"4421\" data-end=\"4496\">CCAM conductor offers good conductivity at lower weight than pure copper.<\/p>\n<\/li>\n<li data-start=\"4497\" data-end=\"4594\">\n<p data-start=\"4499\" data-end=\"4594\">Cost- and weight-efficient for aerial installation compared to armored or full-copper cables.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4596\" data-end=\"4630\"><strong data-start=\"4596\" data-end=\"4628\">Limitations and Precautions:<\/strong><\/p>\n<ul data-start=\"4631\" data-end=\"4838\">\n<li data-start=\"4631\" data-end=\"4743\">\n<p data-start=\"4633\" data-end=\"4743\">Very long distances or high EMI environments may require complex pair design or secondary braided shielding.<\/p>\n<\/li>\n<li data-start=\"4744\" data-end=\"4838\">\n<p data-start=\"4746\" data-end=\"4838\">Shield connection must be properly grounded; improper grounding reduces protective effect.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4840\" data-end=\"4870\"><strong data-start=\"4840\" data-end=\"4868\">Quick Market Comparison:<\/strong><\/p>\n<ul data-start=\"4871\" data-end=\"5078\">\n<li data-start=\"4871\" data-end=\"4981\">\n<p data-start=\"4873\" data-end=\"4981\">Versus unshielded aerial cables: significantly lower noise susceptibility, better for urban installations.<\/p>\n<\/li>\n<li data-start=\"4982\" data-end=\"5078\">\n<p data-start=\"4984\" data-end=\"5078\">Versus full-copper cables: lower cost and weight, may need review under specific conditions.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"5080\" data-end=\"5111\"><strong data-start=\"5080\" data-end=\"5109\">References and Standards:<\/strong><\/p>\n<ul data-start=\"5112\" data-end=\"5487\">\n<li data-start=\"5112\" data-end=\"5193\">\n<p data-start=\"5114\" data-end=\"5193\">General aerial telephone cable documentation (Caledonian Cables \u2014 drop wires)<\/p>\n<\/li>\n<li data-start=\"5194\" data-end=\"5311\">\n<p data-start=\"5196\" data-end=\"5311\">Datasheets and catalogs detailing laminated foil shielding and drain features (Halley \/ Telecommunication cables)<\/p>\n<\/li>\n<li data-start=\"5312\" data-end=\"5398\">\n<p data-start=\"5314\" data-end=\"5398\">International products (Belden, others) showing pair construction with foil\/drain.<\/p>\n<\/li>\n<li data-start=\"5399\" data-end=\"5487\">\n<p data-start=\"5401\" data-end=\"5487\">Conductor and shield quality control standards (Anixter \/ instrumentation catalogs).<\/p>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>1. Technical Section Product Name: Aerial Six-Pair Foil-Shielded Telephone Cable \u00abNoan-A6CCAM\u00bb General Application:Aerial cable for subscriber drop lines and short-distance<\/p>\n","protected":false},"featured_media":1588,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[157,153,150],"product_tag":[],"class_list":{"0":"post-1603","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-cu-aerial-pair-cable","7":"product_cat-paired-cable","8":"product_cat-wire-and-cable","10":"first","11":"instock","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product\/1603","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/comments?post=1603"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/media\/1588"}],"wp:attachment":[{"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/media?parent=1603"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product_brand?post=1603"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product_cat?post=1603"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/novanirco.com\/en\/wp-json\/wp\/v2\/product_tag?post=1603"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}