Technical Section
Product Name: “Noan‑G04F” Underground Telephone Cable
Application: Underground telephone lines with four simultaneous pairs, suitable for underground routes, ducts, and indoor environments requiring protection against noise and environmental conditions.
Internal Structure
-
Conductor: CCAM (Copper‑Clad Aluminum), 60/0 structure (60 fine strands)
-
Effective conductor area: Designed according to project requirements (e.g., ~0.13 mm² or ~0.17 mm²)
-
Pair structure: Four twisted pairs
-
Shield: Laminated aluminum foil wrapped longitudinally around the core (100% coverage)
-
Drain wire: Auxiliary conductor (copper or tinned copper) for grounding the shield
-
Conductor insulation: PVC or PE suitable for underground applications
-
Outer jacket: UV-resistant PVC or composite suitable for outdoor installation
Electrical and Performance Specifications
-
Conductor diameter: Based on reference 4-pair cables, ~0.60 mm per conductor
-
Conductor resistance at 20 °C (max): ≤ 186 Ω/km for ~0.60 mm conductor
-
Insulation resistance (min): ≥ 5000 MΩ·km
-
Test voltage: AC 1500 V (1 min) / DC 2250 V (1 min) without breakdown
-
Operating temperature: ‑20 °C to +60 °C
-
Capacitance and impedance: Twisted pair design reduces crosstalk and inter-pair interference
-
Minimum bending radius: 10× overall cable diameter (or as per manufacturer guidelines)
Installation and Maintenance Notes
-
Install in ducts, underground, or protected pathways
-
Protect crossings with clamps or protective sleeves
-
Connect shield to ground at a single point for optimal performance
-
Avoid sharp bends and maintain proper bending radius
-
Test insulation resistance and line performance after installation
-
Content Section
Noan‑G04F Four-Pair Shielded Underground Telephone Cable
Noan Capital Innovators is proud to present the “Noan‑G04F” cable; a four-pair shielded underground telephone cable designed for indoor and underground environments requiring simultaneous transmission of multiple telephone lines. The lightweight CCAM conductor with 60/0 strand structure, combined with proper insulation and aluminum shielding, ensures high performance against environmental interference. The “Noan‑G04F” is ideal for urban or intercity projects requiring multiple telephone lines in an underground route, offering environmental durability, stable signal, and reliable performance.
Key Features:
-
Four twisted pairs
-
Full foil shield around the core
-
Lightweight CCAM conductor, 60/0 structure
-
Durable design for indoor and underground installation
-
High insulation resistance testing
-
Optimal performance in various environmental conditions
-
Description, Applications, and Comparative Analysis
Suitable Applications:
-
Medium-pair underground telephone lines
-
Underground or in-structure routes in telecom projects
-
Areas with moderate electromagnetic interference
-
Urban or rural areas needing multiple lines in one path
Advantages:
-
Supports multiple telephone lines simultaneously without separate cables
-
Effective noise protection due to foil shielding
-
Reduced installation costs using a single cable for multiple pairs
-
Lighter weight and lower cost compared to full copper cables
Disadvantages:
-
Higher conductor resistance compared to full copper cables
-
Shield effectiveness decreases if not properly grounded
-
Precise adherence to installation standards required
-
Signal loss may be noticeable over long distances
Comparison with Fewer-Pair Models:
-
Compared to one- or two-pair cables, four pairs have higher core density, which may increase inter-pair crosstalk; proper pair twist length and continuous foil design are essential
-
Production cost is slightly higher, but the advantage of multiple lines in a single cable is significant
Quality Assurance and Production Control:
-
Precise control of strand count (60 strands) and conductor uniformity
-
Ensured foil thickness, adhesion, and quality
-
Insulation testing, thermal aging, mechanical and vibration testing on samples
-
Printing product name, Noan Capital Innovators, technical specifications, and production date on the cable
-
Providing customers with insulation resistance and performance test reports

Reviews